Seite 1 - 9,67$&1

K3893V1 3/009,67$9,67$&16HF XULW\6\VWHP8VHU*XLGH® •••••••••••••••••••*

Seite 2

- 10 -About the Keypads (cont'd)ARMEDREADYPANICOFF AWAY STAYMAX TEST BYPASSINSTANT CODE CHIMEREADY1236548970*#®AWAYSTAYINSTANT BYPASSNIGHTALARMC

Seite 3 - TABLE OF CONTENTS

- 11 -About the Keypads (cont'd)NO AC: AC power has been cut off. System is operating on backupbattery power.AC: AC power is present.CHIME: The C

Seite 4 - System Overview

- 12 -Functions of the Keypads6139 2-LINE ALPHA KEYPADFixed-word keypads are functionally similar, except for screen displays.1.DISPLAY WINDOW: Fixed-

Seite 5

Functions of the Keypads (cont'd)- 13 -4.STAY KEY: Arms the perimeterburglary sensors, guardingprotected doors, windows, and otherperimeter prot

Seite 6

Functions of the Keypads (cont'd)- 14 -12. # KEY: Permits arming of thesystem without entering a securitycode (“Quick Arm,” if programmed).A

Seite 7 - Entry/Exit delays

- 15 -Checking for Open ZonesUsing the ✱ KeyBefore arming your system, all protected doors, windows, and otherprotection zones must be closed or

Seite 8 - Entry/Exit delay

- 16 -Arming Perimeter Only(with Entry Delay ON)Using the 3 KeySTAYUse this key when you are staying home, but expect someone to usethe entranc

Seite 9

- 17 -Arming Perimeter and Selected Interior Zones(with Entry Delay ON)Using the 3 Key to Arm Night-StaySTAYUse this key when you are staying h

Seite 10 - About the Keypads

- 18 -Arming Perimeter Only(with Entry Delay OFF)Using the 7 KeyINSTANTUse this key when you are staying home and do not expect anyone touse th

Seite 11

- 19 -Arming All Protection(with Entry Delay ON)Using the 2 KeyAWAYUse this key when no one will be staying on the premises.When armed in AWAY m

Seite 13

- 20 -Arming All Protection(With Entry Delay OFF)Using the 4 KeyMAXUse this key when the premises will be vacant for an extended periodof time,

Seite 14

- 21 -Disarming and Silencing AlarmsUsing the 1 KeyOFFUse the OFF key to disarm the system and to silence alarm andtrouble sounds. See Summary of

Seite 15 - Checking for Open Zones

Disarming and Silencing Alarms (cont'd)- 22 -Memory of AlarmIf an alarm occurs, the keypad displays the zone number(s) thatcaused the alarm and t

Seite 16 - Arming Perimeter Only

- 23 -Bypassing Protection ZonesUsing the 6 KeyBYPASSThis key is used when you want to arm your system with one or morezones intentionally unpro

Seite 17 - (with Entry Delay ON)

Bypassing Protection Zones (cont'd)- 24 -Quick BypassYour system may allow you to easily bypass all open (faulted) zoneswithout having to enter z

Seite 18

- 25 -Chime ModeUsing the 9 KeyCHIMEYour system can be set to alert you to the opening of a door orwindow† while it is disarmed by using CHIME mod

Seite 19 - Arming All Protection

- 26 -Panic Keys(For Manually Activating Silent and/or Audible Alarms)Using Panic KeysYour installer may have programmed your system to use special ke

Seite 20

- 27 -Using Device CommandsGeneral InformationYour system may be set up so that certain lights or other devices canbe turned on or off by using the de

Seite 21 - Using the 1 Key

- 28 -Paging FeatureGeneral InformationIf the Paging feature has been programmed for your system, yourpager will respond to certain conditions as they

Seite 22 - (cont'd)

- 29 -Security CodesGeneral InformationAs an additional safety feature, other users who do not need to knowyour code can be assigned different securit

Seite 23 - Bypassing Protection Zones

- 3 -TABLE OF CONTENTSTABLE OF CONTENTS... 3System Overview... 4General Inf

Seite 24

Security Codes (cont’d)- 30 -Quick ArmingNote that if Quick Arming was programmed by the installer, you canpress the # key in place of the security

Seite 25 - Chime Mode

Security Codes (cont'd)- 31 -To Delete a User1. + 8 (Master Code)Enter 4-digit Master code, then pressthe 8 key.Example: Press 2

Seite 26 - Panic Keys

- 32 -Testing the System(To be conducted weekly)Using the 5 KeyTESTThe TEST key puts your system into a TEST mode, which allows eachprotection p

Seite 27 - Using Device Commands

Testing the System (cont'd)- 33 -Walk in front of any interior motiondetectors (if used) and listen for threebeeps. The keypad should display the

Seite 28 - Paging Feature

- 34 -Trouble ConditionsTypical Check DisplaysThe word CHECK on the keypad's display, accompanied by a rapidbeeping at the keypad, indicates a tr

Seite 29 - Security Codes

Trouble Conditions (cont'd)- 35 -Telco Fault(or CHECK andzone 94)If the telephone line monitor feature has beenprogrammed for your system, this d

Seite 30 - (cont’d)

Trouble Conditions (cont’d)- 36 -POWER indicator(if present) is off.AC LOSS isdisplayed.The system is operating on battery power only.If only some lig

Seite 31

- 37 -Fire Alarm System(If Installed)General InformationYour fire alarm system (if installed) is active 24 hours a day,providing continuous protection

Seite 32 - Testing the System

Fire Alarm System (cont’d)- 38 -2. If the keypad indicates a trouble condition after the second OFFsequence, check smoke detectors to see if they are

Seite 33

- 39 -Recommendations for Proper ProtectionTHE FOLLOWING RECOMMENDATIONS FOR THE LOCATION OF FIREAND BURGLARY DETECTION DEVICES HELP PROVIDE PROPERCOV

Seite 34 - Trouble Conditions

- 4 -System OverviewGeneral InformationCongratulations on your ownership of an ADEMCO Security System.You've made a wise decision in choosing thi

Seite 35 - (cont'd

Recommendations for Proper Protection (cont’d)- 40 -DININGKITCHENBEDROOMBEDROOMBEDROOMBEDROOMLIVING ROOM✪✪✪✪✪▲▲BEDROOMBDRMBDRMDINING LIVING ROOMTV ROO

Seite 36

Recommendations for Proper Protection (cont'd)- 41 -Recommendations for Proper Intrusion ProtectionFor proper intrusion coverage, sensors should

Seite 37 - Fire Alarm System

- 42 -Emergency EvacuationEstablish and regularly practice a plan of escape in the event of fire. The followingsteps are recommended by the National F

Seite 38

- 43 -Maintaining Your SystemTaking Care of Your SystemThe components of your security system are designed to be asmaintenance-free as possible. Howev

Seite 39

Maintaining Your System (cont’d)- 44 -Important: Use only batteries recommended by your installer asreplacement.Silencing Low Battery Warning Tones a

Seite 40

- 45 -Quick Guide to System FunctionsFUNCTION PROCEDURE COMMENTSCheck ZonesPress [✴]Do this to view faulted zones when system isnot ready.Arm System E

Seite 41

- 46 -Summary of Audible Notification(Alpha Display Keypads)SOUND CAUSE DISPLAYLOUD, INTERRUPTED*Keypad & ExternalFIRE ALARMFIRE is displayed; des

Seite 42 - Emergency Evacuation

- 47 -GlossaryThe following terms are used throughout the manual.ARM/DISARM:"Armed" simply means that the burglary portion of your systemis

Seite 43 - Maintaining Your System

- 48 -UL NOTICE: This is a "GRADE A" system.FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENTThis equipment has been tested to FCC r

Seite 44

- 49 -FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICEThis equipment complies with Part 68 of the FCC rules. On the front cover of thisequipment

Seite 45 - FUNCTION PROCEDURE COMMENTS

- 5 -System Overview (cont'd)The following table lists the five different arming modes and thefeatures of each.FEATURES OF EACH ARMING MODEARMING

Seite 46 - (Alpha Display Keypads)

- 50 -WARNING!THE LIMITATIONS OF THIS ALARM SYSTEMWhile this system is an advanced design security system, it does not offer guaranteed protectionagai

Seite 47 - Glossary

- 51 -WARNING!THE LIMITATIONS OF THIS ALARM SYSTEM (cont'd)• Alarm warning devices such as sirens, bells or horns may not alert people or wake up

Seite 48

- 52 -CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC)STATEMENTNOTICEThe Canadian Department of Communications labelidentifies certified equipment. This ce

Seite 49

- 53 -OWNER’S INSURANCE PREMIUM CREDIT REQUESTThis form should be completed and forwarded to your homeowner’s insurance carrier for possiblepremium cr

Seite 50 - WARNING!

- 54 -OWNER’S INSURANCE PREMIUM CREDIT REQUEST(cont.)E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic

Seite 51

- 55 -IndexAC Loss...36Add a User... 30Alarm ...

Seite 52 - STATEMENT

¬.9JlK3893V1 3/00ADEMCO ONE YEAR LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions,subsid

Seite 53 - Address Address

- 6 -System Overview (cont'd)Cross ZoningCross zoning is used to prevent false alarms. Up to 10 zones can be linkedtogether in your security syst

Seite 54

- 7 -Entry/Exit delaysGeneral InformationThe VISTA-15 has preset time delays, known as exit delay and entrydelay. Whenever you arm your system, exit d

Seite 55

- 8 -Entry/Exit delay (cont'd)Exit AlarmsTo minimize false alarms sent to the alarm monitoring company,your system may have been programmed for t

Seite 56 - ¬.9Jl

- 9 -About the KeypadsIMPORTANTIf the keypad beeps rapidly when you enter the premises, itmeans that an alarm has occurred during your absence and ani